Leaks can be due to multiple sources of water penetration. For this 1930 school and its 1999 addition, SUPERSTRUCTURES used masking, leakage mapping, and water deluge testing on the exterior and infrared thermography and electrical capacitance testing on the interior. All sources were identified, ensuring that all necessary and no unnecessary repairs would be specified.